Ration Batching Controller Electronic Weighing Indicator For 5-Material Ration Batching Scale
Main Features:
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation | |
Key Name | Description |
【MENU】 | Enter Main Menu / Exit. |
【ENT】 | Enter / Save / Alarm Acknowledge. |
【◄】 | Cursor shifts left. |
【►】 | Cursor shifts right. |
【▲】 | Display the previous interface or option. Digit input: +1. |
【▼】 | Display the next interface or option. Digit input: -1. |
Quick Operation | |
【Ñ】 * |
|
【SET】 | M1~M5 Target Values setting. |
【G/N】 | Gross Weight / Net Weight display switch. |
【→C←】 【CAL】 * | Load Calibration. |
【→0←】 【ZERO】 * |
|
【→T←】 【TARE】 * |
|
【,】* | Record Query. |
【/】* | Clear Screen: Clear the display value of Tatal Feeding Weight, Totalized Weight and Batch Count. |
【‡】* | Time display and setting. |
【±】 | ‘+’/‘-’ switch. |
【6】 | Main Display Interface:
Record Query state: Print Historical Batch Record. |
【ENT】 | Pause State:
|
Sign | Description |
[GROSS] | Gross Weight display. |
[NET] | Net Weight display. |
[LOCK] | ON: Key-locked. OFF: Key-unlocked. |
[◣◢] | Weight is stable: Weight Variance per [107] ‘Stablity Judging Time’ is in [106] ‘Stablity Judging Range’. |
[→0←] | The present Gross Weight or Net Weight display value is in ‘Display Value Auto-Zero Range’. |
[kg/t/g] | Weight unit. |
[ NUM] | Material No. display. |
[ PCS] | Batch Count display. |
[TOT] | Totalized Weight display. Total Feeding Weight display. |
[SET] | Target Value display. Parameter setting state. |
[RUN] | ON: Running state. Blinking: Pause state. OFF: Stop or Calibrating state. |
[ZERO] | Net Weight ≤ Non-load Zero Range. |
[NZ] | It’s allowed to do Zero Fine Adjustment. |
[SP1] | High-speed Feeding. |
[SP3] | Low-speed Feeding. |
[FILL] | Stop state: Weight value is increasing. |
Running state: It’s in the feeding process. | |
[COMP] | ON: It’s doing comparation between Feeding Weight and Target Value. OFF: It turns off in Comparing-prohibited Time. |
[DEV] | Positive/Negative Deviation Alarm. |
[FALL] | ON: Fall Value Auto Correction function is open. |
[DISC] | Stop state: Weight value is reducing. |
Running state: It’s in the dumping process. | |
[HH] | Gross Weight Upper Limit Alarm. |
Sign | Alarm Cause | Solution |
Err1 | RAM Failure. | Replace the chip RAM. |
Err2.1 Err2.2 | EEPROM Failure. | Replace the chip EEPROM. |
Err3 | Signal reversed or not connected. | Connect the loadcell correctly. |
Err4 | ADC Failure. | Replace the ADC module. |
oV-Ad | Over ADC Range. | Weighing signal exceeds A/D conversion range. 1. Check if the loadcell is connected. 2. Check if the capacity of loadcell is too small. 3. Check if the loading weight is too big. |
oL | Overload Alarm. | Gross Weight > (Scale Capacity + 9 × Scale Division). 1. Check if the loadcell is connected. 2. Check if the capacity of loadcell is too small. 3. Check if the loading weight is too big. |
HH | Gross Weight Upper Limit Alarm in Stop state. | Refer to parameter [209] ‘Gross Weight Upper Limit’. 1. Modify the set value of ‘Gross Weight Upper Limit’ if it’s too small. 2. Do ‘Manual Dump’ if the weighing hopper has been filled with too much materials. |
Pr-PAUSE | Pause state with unexpected power-off. | With unexpected power-off in the auto-batching process, the controller will enter pause state after re-power-on. Press DI button ‘Start/Dev.Ack’ or【ENT】to recover running. |
HH-PAUSE | Pause state with Gross Weight Upper Limit Alarm in the auto-feeding process. | Refer to parameter [209] ‘Gross Weight Upper Limit’. 1. Modify the set value of ‘Gross Weight Upper Limit’ if it’s too small, and then press DI button ‘Start/Dev.Ack’ or【ENT】to recover running. 2. Stop batching and do ‘Manual Dump’ if the weighing hopper has been filled with too much materials. |
dI-PAUSE | Manual Pause. | Press DI button ‘Start/Dev.Ack’ or【ENT】to recover running. |
OV-PAUSE | Pause state with Positive Deviation Alarm. | Press DI button ‘Start/Dev.Ack’ or【ENT】to recover running. |
dn-PAUSE | Pause state with Negative Deviation Alarm. | It’s allowed to do ‘SP3 Manual Re-feed’. Press DI button‘Start/Dev.Ack’ or【ENT】to recover running. |
CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID
Changsha SUPMETER Technological Co., Ltd., as a council member of China Weighing Instrument Association (CWIA), is a high-tech enterprise which specializes in designing and manufacturing weighing/batching controller, force measuring controller, explosion-proof controller and related system software.
Since founded in 2004, SUPMETER is persisting in doing the same thing of ‘customizing satisfied products for you and building win-win cooperation with you’ and insisting on the core idea of ‘Being Super in Meter and Being Perfect in Service’. On the quality basic of ‘Accurate Weighing, Quick and Steady Control, Standard Communication Bus and Protocol, Suitable for Industrial Environment’, SUPMETER is doing the best to meet your individual requirements and to reach the enterprise goal of ‘Outstanding Quality, Continuous Improvement, Effective Service and Customer Satisfaction’.
The products of SUPMETER have been sold to over 1000 weighing equipment manufacturers from China, Germany, USA, Canada, Australia, Russia, Ukraine, Uzbekistan, Turkey, Pakistan, India, Thailand, Vietnam, Philippines, Malaysia, Indonesia, Singapore, Sri Lanka, South Africa, Nigeria, Zimbabwe, Iran, Saudi Arabia, Jordan, United Arab Emirates, Oman, Palestine, Mexico, Brazil, Argentina, Venezuela, Honduras, Bolivia, Chile, Peru and other countries and regions. And we have built long-time relationship of technical exchange and co-development with many famous enterprises. By tracking and applying international advanced technology and combining with all kinds of typical applications from the worldwide customers, SUPMETER has developed multiple high-quality products for customers and became a famous enterprise and brand in weighing, batching and force measuring field.
We will do our best to make our development more high-efficiency, quality more superior, service more enthusiastic and price more reasonable. SUPMETER, as your faithful team of product-development and technical service, is one of your best choices.
Executing Standard & Product Certification: